How To Solve The Problems Of GW42D-4
Nov 22, 2022| After-sales solution for GW42D-4
Installation requirements


Simply Repair
Failure phenomenon | Reason | Processing method |
Working disk does not rotate | No line voltage or connection error | Check in line |
Emergency stop button is not released | Clockwise rotation of the emergency stop button | |
Fuse destroyed | Replacement fuse | |
Continuous rotation of working disk
| The reversed limit switch has no action or both limit switches are damaged. | Repair or replace after examination |
The forward and reverse buttons are stuck during manual operation | Repair or replace | |
Reversing Contactor Contact Bonding | Repair or replace | |
Can't bending large steel bar | Low voltage | Check voltage in the range of 380V + 5 |
V-belt slips loose | Tensioned trigonometric belt | |
Damage of key groove of triangulation wheel | Repair or replace a triangular belt wheel | |
Inaccurate angle of bending | Stroke stop block loosening | Fastening stroke stop block |
Motor brake screw loosening | Adjust and fasten motor brakes | |
Stroke switch damage | Repair or replace | |
Abnormal sound or body fever | Gear damage | Repair or replace |
Bearing damage | Repair or replace | |
Overfuel | Release excess lubricant until it reaches the middle of the oil window | |
Motor scalding | Overload use | As required by the instructions |
Low voltage | Check voltage in the range of 380V + 5 | |
Contact contact of AC contactor | Replace contact or AC contactor | |
Tooth box bearing or gear damage | Replacement of bearing or gear damage |


Machine Maintenance
The first time to replace the lubricating oil is after three months. It is best to replace the hot machine state that has just been used. Open the drain plug on the lower gearbox and drain off the waste oil. Then start the motor, remove the remaining waste oil, tighten the oil stopper and add clean gear oil.
Before l bending steel bar, the pile head and pile head sleeve should be selected according to the strength and diameter of the steel bar.
After working for a period of time, l should convert the working disk to 180 degrees and then use it, so that the large gear in the deceleration box is converted to 180 degrees, so that the gear can be evenly worn and the service life of the machine is prolonged.
After each class is finished, the workbench should be cleaned and grease applied to the working face. It is strictly prohibited to refuel or wipe the machine during the operation.
It is not allowed to change center pile head, retaining head or baffle plate during operation.
The bars that are not straight should not be bent on the bending machine to prevent accidents.
When the machine is shut down for a long time, rust proof grease should be applied to the surface of the machine and placed in the dry place of the room.